Four-Channel Cross Hole Sonic Logging Test System
Pile Foundation Testing Equipment

Four-Channel Cross Hole Sonic Logging Test System

Model: BP-4CSL

Advanced four-channel cross-hole sonic logging system with 12.1-inch sunlight-readable color LCD touch screen. Allows four probes (six profiles) to be pulled at once for efficient data collection.

Request Quote

Key Features

12.1-inch sun light readable color LCD touch screen visible in all lighting conditions
Four probes (six profiles) pulled at once for ease and efficiency
Color coded wires for easy identification of probe
Advanced algorithm for automatic first arrival time detection
Depth, first arrival time, wave-speed, amplitude displayed simultaneously in real-time
Bluetooth depth counter, wire or wireless connection
Real-time analysis on site with PC reporting software
Bluetooth data transmission, real-time upload via mobile APP
Replaceable battery and USB ports for quick data transfer

Technical Specifications

Display12.1-inch sun light readable color LCD touch screen
Memory32GB
Sampling Interval0.025μs~2000μs adjustable
Record Length0.5~4000
Acoustic Transit Time Range80000000μs
Emission Voltage125, 250, 500, 1000V adjustable
Sampling Length512, 1024, 2048, 4096 adjustable
Amplifier Gain130dB
Amplifier Gain Accuracy0.5dB
Channels4
Tested Profiles Per Time6
Max Lifting Speed60m/min
Depth RecordDouble direction record
Emission Pulse Width0.1~100μs
Band Width1~500kHz
Amplitude Accuracy≤3%
Acoustic Time Accuracy≤0.5%
Receiver Sensitivity≤10μv
Channels Interference≤1/400
Transmission PortUSB, WIFI, Bluetooth
Working Temperature-20℃~+50℃
BatteryReplaceable, working more than 8 hours
Record Interval Depth2~25cm
Depth Resolution1cm
Size340x256x58mm
Weight3.5kg

Applications

Determines the quality and consistency of concrete foundations including drilled shafts, slurry walls, bored piles, cast-in-situ piles; Ultrasonic and rebound comprehensive method for testing concrete strength; Concrete internal defect detection and positioning; Concrete crack depth detection.

Applicable Standards

JGJ 106-2014 - Technical Code for Detection of Building Foundation Pile

Interested in Four-Channel Cross Hole Sonic Logging Test System?

Contact our sales team for pricing, availability, and technical consultation.

Request Quote